Lynx Solar Evacuated Tube Solar Collector
Lynx Solar Evacuated tube collectors can be used in Commercial and domestic hot water and heating systems
WHY USE EVACUATED TUBE COLLECTORS?
- Lynx Solar evacuated tube collectors have high efficiency in capturing and converting the sun's energy, which is free and we can then use it to our advantage.
- Due to the design of the Lynx Solar evacuated tube collector, both heat and light are captured, taking in the sun's rays from sun-up to sun-down. Flat plate panels only have the best of the sun at midday so are less efficient and therefore more square meters of collector are needed to obtain the same energy.
- Lynx Solar evacuated tubes give excellent performance in winter and can stand up to high winds and hailstones.
- Lynx Solar evacuated tube collectors are now very affordable and give a good return for money spent by saving energy costs.
SPECIFICATIONS
About Materials Employed:
- Outer manifold: aluminium alloy
- Header pipe within the manifold : copper
- Insulation within the manifold rock wool
- Sealing stabilized high temperature silicon
- Evacuated tube: borosilicate glass 3.3; absorb coating
- Heat pipe: copper
- Collector frame: stainless steel
- Suitable for mains pressure
EVACUATED TUBE TECHNICAL DATA
|
Inner glass tube diameter |
47 mm |
|
Outer glass tube diameter |
58 mm |
|
Thickness of glass |
1.6 mm |
|
Total weight |
2.2 Kg. |
|
Glass material |
Borosilicated Glass 3.3 |
|
Absorber coatings used |
A1/N/A1 |
|
Temperature in insolation |
>200ºC |
|
Freeze resistant |
-35ºC |
|
Hailstone resistant |
25mm diameter |
|
Wind resistant to |
30m/s 108Km/s |
|
Temperature needed for start up |
25ºC |
|
Heat Loss |
>0.8 (m2ºC) |
|
Absorbance |
93% |
- Each complete evacuated tube is made of two glass tubes (one inside the other) made out of 3.3 high boron glass
- Three coats of high absorbing material used -- AL/N/AL -- are designed to absorb and retain all available heat
- The evacuated tube has a high absorbing efficiency
- Evacuated tubes life span of 15 years
About Each Model:
| MODEL |
Dia. |
Length |
Qty. |
Produce |
|
Heat pipe (mm) |
Heat pipe (mm) |
Heat pieces (pcs) |
Hot water (L) |
|
|
SF-1800/58-10-AC |
58 |
1800 |
10 |
100 |
|
SF-1800/58-20-AC |
58 |
1800 |
20 |
170 |
|
SF-1800/58-24-AC |
58 |
1800 |
24 |
200 |
|
SF-1800/58-30-AC |
58 |
1800 |
30 |
250 |
Guarantee of evacuated tubes 10 years
INTERNATIONAL QUALITY CERTIFICATIONS
- The whole product has CE approval
- DAS certification Ltd. (Member of The International Accreditation Forum, Inc. ISO 9001:2000
- (IAF) Recognition arrangement
- Certificate of Conformity Schenzen LCS Certification Services Inc.: EN 12975-1; EN 12975-2; EN 12976-1.